FAST + FREE Shipping & Returns on all orders above $499.99

FAST + FREE Shipping & Returns on all orders above $499.99

The Role of a Refrigerated Air Dryer

A refrigerated air dryer is a device used to dry and purify compressed air. Its specific functions are as follows:

1. Moisture Removal (Core Function)

Compressed air releases a significant amount of liquid water as it cools. The refrigerated dryer lowers the temperature of the compressed air, causing water vapor to condense into liquid. This liquid is then separated and discharged. This process achieves a pressure dew point, preventing water from accumulating in pipes and downstream equipment.

2. Preventing Pipe Corrosion and Ice Blockage

Dry air effectively prevents rust inside ferrous pipes and stops any residual moisture from freezing and causing blockages or burst pipes in low-temperature environments.

3. Protecting Downstream Equipment

– Prevents pneumatic components (like cylinders and valves) from seizing or wearing out due to rust and scale.

– Prevents water from emulsifying lubricating oil, which reduces lubrication effectiveness and can damage pneumatic tools.

4. Ensuring Product Quality

In industries such as painting, food packaging, precision instruments, and pharmaceuticals, moisture in compressed air can cause defects like bubbles on painted surfaces, spoilage of drugs, or oxidation of electronic components.

5. Reducing Maintenance Costs

Reduces the burden of water removal on downstream components like drains and filters, extending their service life and repair intervals.

Important Limitations: A refrigerated dryer may not be suitable if the ambient temperature is very high, if a very low dew point is required, or if corrosive gases need to be processed. In these cases, a desiccant dryer or a combined air dryer system would be necessary.

<div

style="margin-top:12px;font-size: 16px; font-weight:bold;line-height:24px;color: #333333;word-break: break-word;">Use-friendly Control Panel

It simplifies complex operations, enabling users whether professionals or general users to monitor and manage equipment or systems with ease, accuracy, and safety.

<div

style="margin-top:12px;font-size: 16px; font-weight:bold;line-height:24px;color: #333333;word-break: break-word;">Low Pressure Guage

To check the low-pressure side of a ventilation system or refrigeration equipment.

High Pressure Guage

Check the high-pressure side of the ventilation system or refrigeration equipment.

<div

style="margin-top:12px;font-size: 16px; font-weight:bold;line-height:24px;color: #333333;word-break: break-word;">Air Inlet

NPT 1 1/2" Air Inlet

<div

style="margin-top:12px;font-size: 16px; font-weight:bold;line-height:24px;color: #333333;word-break: break-word;">Air Outlet

NPT 1 1/2" Air Outlet

Automatic Drainage

The benefits of automatic drainage are numerous, primarily reflected in improved efficiency, enhanced safety, cost savings, and equipment protection.

Parameters of 240CFM Refrigerated Air Dryer-115V / 60HZ / 1-Phase

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Air Handling Capacity

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">240 CFM

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Pressure Dew Point

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">37.4-50 °F

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Standard Working Pressure

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">101.5 PSI

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Maximum Working Pressure

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">145 PSI

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Air Inlet Temperature

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">≤140 °F

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Ambient Temperature

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">≤100.4 °F

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Adaptation to The Work System

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Continuous work

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Pressure Loss

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">≤2.9 PSI

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Blowdown Valve

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Electronic blowdown valve

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Cooling Method

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Air cooling

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Refrigerant

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">R410a

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Power Supply

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">115V / 60Hz / 1-Phase

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Cooling Power

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">1.5 HP

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Fan Power

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">150 W

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Import and Export Pipe Size

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">NPT 1-1/2"

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Product Dimension

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">35.04 x 18.9 x 33.86 INCH

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Net Weight

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">216.05 LBS

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Pacakge Dimension

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">37.8 x 21.26 x 40.55 INCH

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Gross Weight

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">265.66 LBS

Features

  • 240CFM Refrigerated Air Dryer for 50HP Air Compressors
  • Designed for industrial and workshop compressed air systems
  • it delivers high-capacity drying performance for industrial facilities that operate three-phase electrical systems.
  • Refrigerated Air Compressor Dryer, Compressed Air Systems, Industrial Refrigerated Compressed Air Dryer

Specifications

Main MaterialMetal
Main ColorBlack+Blue
OriginChina
Main ColorBlack+Blue
Product StyleIndustrial
Main MaterialMetal
Assembled Size35.04 x 18.90 x 33.86 inches

240CFM Refrigerated Air Dryer for 50HP Air Compressors, 1 PHASE 115V, Refrigerated Air Compressor Dryer, Compressed Air Systems, Industrial Refrigerated Compressed Air Dryer

$3,056.99

Availability: 2 in stock

The Role of a Refrigerated Air Dryer

A refrigerated air dryer is a device used to dry and purify compressed air. Its specific functions are as follows:

1. Moisture Removal (Core Function)

Compressed air releases a significant amount of liquid water as it cools. The refrigerated dryer lowers the temperature of the compressed air, causing water vapor to condense into liquid. This liquid is then separated and discharged. This process achieves a pressure dew point, preventing water from accumulating in pipes and downstream equipment.

2. Preventing Pipe Corrosion and Ice Blockage

Dry air effectively prevents rust inside ferrous pipes and stops any residual moisture from freezing and causing blockages or burst pipes in low-temperature environments.

3. Protecting Downstream Equipment

– Prevents pneumatic components (like cylinders and valves) from seizing or wearing out due to rust and scale.

– Prevents water from emulsifying lubricating oil, which reduces lubrication effectiveness and can damage pneumatic tools.

4. Ensuring Product Quality

In industries such as painting, food packaging, precision instruments, and pharmaceuticals, moisture in compressed air can cause defects like bubbles on painted surfaces, spoilage of drugs, or oxidation of electronic components.

5. Reducing Maintenance Costs

Reduces the burden of water removal on downstream components like drains and filters, extending their service life and repair intervals.

Important Limitations: A refrigerated dryer may not be suitable if the ambient temperature is very high, if a very low dew point is required, or if corrosive gases need to be processed. In these cases, a desiccant dryer or a combined air dryer system would be necessary.

<div

style="margin-top:12px;font-size: 16px; font-weight:bold;line-height:24px;color: #333333;word-break: break-word;">Use-friendly Control Panel

It simplifies complex operations, enabling users whether professionals or general users to monitor and manage equipment or systems with ease, accuracy, and safety.

<div

style="margin-top:12px;font-size: 16px; font-weight:bold;line-height:24px;color: #333333;word-break: break-word;">Low Pressure Guage

To check the low-pressure side of a ventilation system or refrigeration equipment.

High Pressure Guage

Check the high-pressure side of the ventilation system or refrigeration equipment.

<div

style="margin-top:12px;font-size: 16px; font-weight:bold;line-height:24px;color: #333333;word-break: break-word;">Air Inlet

NPT 1 1/2" Air Inlet

<div

style="margin-top:12px;font-size: 16px; font-weight:bold;line-height:24px;color: #333333;word-break: break-word;">Air Outlet

NPT 1 1/2" Air Outlet

Automatic Drainage

The benefits of automatic drainage are numerous, primarily reflected in improved efficiency, enhanced safety, cost savings, and equipment protection.

Parameters of 240CFM Refrigerated Air Dryer-115V / 60HZ / 1-Phase

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Air Handling Capacity

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">240 CFM

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Pressure Dew Point

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">37.4-50 °F

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Standard Working Pressure

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">101.5 PSI

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Maximum Working Pressure

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">145 PSI

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Air Inlet Temperature

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">≤140 °F

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Ambient Temperature

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">≤100.4 °F

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Adaptation to The Work System

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Continuous work

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Pressure Loss

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">≤2.9 PSI

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Blowdown Valve

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Electronic blowdown valve

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Cooling Method

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Air cooling

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Refrigerant

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">R410a

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Power Supply

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">115V / 60Hz / 1-Phase

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Cooling Power

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">1.5 HP

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Fan Power

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">150 W

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Import and Export Pipe Size

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">NPT 1-1/2"

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Product Dimension

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">35.04 x 18.9 x 33.86 INCH

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Net Weight

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">216.05 LBS

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Pacakge Dimension

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">37.8 x 21.26 x 40.55 INCH

<td

style="width: 40%;line-height:24px;padding: 12px 16px;background: #F7F8FA;border-right: 1px solid #E5E5E5;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">Gross Weight

<td

style="width: 60%;line-height:18px;padding: 12px 16px;border-bottom: 1px solid #E5E5E5;word-break: break-word;white-space: pre-wrap">265.66 LBS

Features

  • 240CFM Refrigerated Air Dryer for 50HP Air Compressors
  • Designed for industrial and workshop compressed air systems
  • it delivers high-capacity drying performance for industrial facilities that operate three-phase electrical systems.
  • Refrigerated Air Compressor Dryer, Compressed Air Systems, Industrial Refrigerated Compressed Air Dryer

Specifications

Main Material Metal
Main Color Black+Blue
Origin China
Main Color Black+Blue
Product Style Industrial
Main Material Metal
Assembled Size 35.04 x 18.90 x 33.86 inches
Weight 265.66 kg
Dimensions 40.55 × 37.8 × 21.26 cm
Main Color

Black+Blue

Product Style

Industrial

Main Material

Metal

Reviews

There are no reviews yet.

Be the first to review “240CFM Refrigerated Air Dryer for 50HP Air Compressors, 1 PHASE 115V, Refrigerated Air Compressor Dryer, Compressed Air Systems, Industrial Refrigerated Compressed Air Dryer”

Your email address will not be published. Required fields are marked *

Estimated Handling Time

Handling time is 0–1 business days (Monday to Friday).

Estimated Shipping Time

Transit time is 2–4 business days (Monday to Friday).

Related Products

Authorized dealer for 180+ brands Free shipping over $499.99 Lifetime return window US-based support, Mon-Fri 9-6 PST Secure checkout
Secure Site256-bit SSL encrypted
Safe CheckoutYour details stay private
Authorized Dealer180+ brands, factory-direct
Scroll to Top