Reach-in refrigerator sizes come in three common widths, set by the number of sections. On the spec sheets and listings we checked, a one-section (one door) cabinet runs about 27 to 30 in wide, a two-section runs about 52 to 54 in, and a three-section runs about 76 to 81 in. Capacity follows width: roughly 19 to 24 cubic feet for one section, 42 to 46 for two, and about 69 to 72 for three. Most full-height models stand roughly 80 to 84 in tall on casters.
Width is only part of the decision. Depth with the door, overhead clearance, your doorways and the door style matter too. Below are real numbers from Traulsen spec sheets and units we carry.
Reach-in refrigerator sizes at a glance
Dimensions are width x depth x height in inches, from Traulsen’s G-Series spec sheets and our listings.
| Model | Sections and doors | Size (in) | Capacity |
|---|---|---|---|
| Traulsen G-Series 1-section solid door (spec sheet) | 1 section, 1 full or 2 half doors | 29-7/8 W x 32 D x about 83-3/8 H | 23.43 cu ft |
| Traulsen G-Series 2-section solid door (spec sheet) | 2 sections | 52-1/8 W x 32 D x 83-3/8 H | 46.02 cu ft |
| Traulsen G-Series 3-section solid door (spec sheet) | 3 sections | 76-3/8 W x 32 D x 83-3/8 H | 69.35 cu ft |
| 27 in wide solid door reach-in | 1 section, 1 door | 26.89 W x 30.71 D x 81.89 H | 18.68 cu ft |
| Migali C-1R-HC | 1 section, 1 door | 28.7 W (listing gives width only) | 23.0 cu ft |
| 29 in Dynamic Cooling reach-in | 1 section, 1 door | Listed as 33.90 x 27.10 x 79.70 (order not stated) | 23 cu ft |
| 54 in wide two-door reach-in | 2 sections, 2 doors | 54.13 W x 30.71 D x 81.89 H | 42.2 cu ft |
| Hurakan HKN-GXE72R3E | 3 sections, 3 doors | About 81 W (per listing) | 72 cu ft |
Note that Traulsen’s 32 in depth excludes the door and handle, which add 3-1/8 in, for about 35-1/8 in total.
Commercial reach-in refrigerator dimensions: what to measure
Width and section count
A section is one interior compartment with its own full door or pair of half doors. Section count drives width and capacity, so measure your wall space first.
Height and overhead clearance
Traulsen’s height includes 6 in casters, and its spec sheets say 12 in of top clearance is preferred. The owner’s manual says the condensing unit needs at least 12 in overhead or unrestricted airflow at the back, and 12 in above is required for some maintenance. By our math, a top-mount Traulsen needs about 95-3/8 in to the ceiling or soffit.
Depth and the door swing
The manual says the door must open at least 90 degrees to use the full clear door width, and asks for room at the side wall to use the 120 degree stay-open feature. Traulsen sells left and right hinged versions, so pick the hinge side before you order.
Getting it through the door
Measure every doorway and turn on the delivery path. Traulsen’s manual says doors and hinges may need to come off for doorways narrower than 35 in, and removing the lock keeper brings depth to 32 in. If your path is tight, call us before you buy. The commercial kitchen equipment guide covers delivery planning in more detail.
1 door vs 2 door commercial refrigerator
A one-door reach-in suits small kitchens, bars, cafes and secondary storage. A two-door unit roughly doubles capacity in 52 to 54 in of wall. On the Traulsen sheets, two sections hold 46.02 cu ft and draw 4.3 amps, against 23.43 cu ft and 3.8 amps for one section, all on 115 volt NEMA 5-15P plugs. Three sections list 69.35 cu ft and 7.9 amps.
Two singles give you redundancy and can sit in different spots. One two-door unit needs one outlet instead of two, and Traulsen’s manual requires a dedicated circuit with no extension cord, so count outlets first.
How many cubic feet commercial refrigerator do you need?
None of the sources we opened publish a cubic feet per seat formula, so count what you store instead. Each Traulsen G-Series section ships with three adjustable shelves, and optional trayslides hold one 18 x 26 in sheet pan or two 14 x 18 in pans per level. Count the pans you need cold at once and size by levels. Listed capacity is total volume, and Traulsen’s Load-Sure guards exist to stop overloading that blocks airflow, so do not plan on filling every cubic foot.
Solid door vs glass door reach-in
Solid doors suit back-of-house storage. Glass doors let staff or customers see inside without opening. The Traulsen G11010 is a one-section glass door model listed at 23.57 cu ft with LED interior lights, while the Traulsen G10010 is the solid door version listed at 23.4 cu ft.
Half doors or full doors
Half-height doors split each section into an upper and lower opening. The Traulsen G10000 uses two half doors on one section, and its listing says they help limit cold air loss. The Traulsen G12000 freezer uses the same layout.
Top mount vs bottom mount
Top-mount units put the refrigeration system on the cabinet roof. Traulsen says its top-mounted, front-facing coil takes in less floor dirt (a manufacturer claim); the tradeoff is the overhead clearance above. Bottom-mount units put the system near the floor instead. Read the clearance section of any spec sheet before you commit.
Temperature, certifications and energy
Under section 3-501.16 of the FDA Food Code 2022, time/temperature control for safety food held cold must be kept at 41°F or less. Traulsen rates its G-Series reach-in refrigerators to operate at 34 to 38°F. The 27 in solid door unit in our table lists 33 to 39°F, and the Migali lists 33 to 41°F. Check with your local health department too.
Traulsen states its equipment is listed to applicable UL, CSA and NSF standards, and its one- and two-section solid door sheets carry the ENERGY STAR listed mark. Traulsen claims its latest designs could save up to 45 percent in annual energy costs versus a non-ENERGY STAR cabinet. The Migali listing also states ENERGY STAR certification. For other models, call us to confirm.
See also our guides to the drop-in cold food well and the best commercial ice makers for small restaurants, plus our commercial fryer size guide.
Frequently asked questions
What is the standard width of a one-door reach-in refrigerator?
There is no single standard. The one-section models we checked range from 26.89 in (a 27 in solid door unit) to 29-7/8 in (Traulsen G-Series). Always confirm the exact width on the spec sheet.
How deep is a commercial reach-in refrigerator?
The ones we checked list about 30.7 to 32 in of cabinet depth. Traulsen adds 3-1/8 in for the door and handle, so plan on roughly 35 in from the wall.
Will a reach-in fit through a standard doorway?
Traulsen’s manual says doors or hinges may need to come off for doorways narrower than 35 in. Measure the full delivery path and call us before ordering if it is tight.
Do I need a special outlet?
The Traulsen G-Series one-, two- and three-section refrigerators use 115 volt power with a NEMA 5-15P plug, and the manual requires a dedicated circuit. Check each listing for its own electrical data.
How much does shipping cost?
Freight shipping is free on orders of $999 or more, and $200 flat below that. Call 866-777-2590, Monday to Friday 9AM to 6PM PST, with sizing questions. Our return and refund policy is online, and you can browse every Traulsen model we carry.
Sources: Traulsen G-Series refrigerators and freezers (product page, spec sheets and owner’s manual) and the FDA Food Code 2022.